SPECIFICATION
SHEET
September 2006 |
DURLON® 8300
Carbon Fiber with NBR Rubber Binder
COMPRESSED SHEET GASKET MATERIAL
ASTM F104: F712120-A9B3E22K5L311M5 |
|
 |
APPLICATION:

DURLON®
8300 is premium grade compressed sheet gasket material that is
excellent in steam and hydrocarbon services in the refining,
petrochemical and power generation industries. Other applications
include oil, water, mild alkalis, mild acids, and solvents.
COMPOSITION:

DURLON® 8300 contains high-strength
carbon fibers bonded with nitrile (NBR) synthetic rubber. A release agent on both sides
provides good anti-stick properties.
ANTI-STICK PROPERTIES:

Much effort
has gone into improving the anti-stick release agents of all compressed
DURLON®
products. All DURLON®
compressed gasket materials have passed the
MIL-G-24696B Navy Adhesion Test (366°F/48 hrs).
|
TYPICAL
PROPERTIES:
|
Color: |
Black, branded |
| Fiber: |
Carbon |
| Binder: |
Nitrile (NBR) |
|
Fluid Services: |
Saturated Steam, Oils, Dilute Acids &
Alkalis, Hydrocarbons, Solvents |
| Density: |
1.6 g/cm3 (100 lbs./ft3) |
| Tensile Strength, ASTM F152: |
1,800 psi (12.4 MPa) |
| Compressibility, ASTM F36: |
8 to 16% |
| Recovery ASTM F36: |
50% |
Temperature
Range:
Continuous, max: |
-100 to 800°F (-73 to 427°C)
600°F (315°C) |
| Pressure, max: |
1500 psig (103 bar) |
Fluid Resistance - ASTM F146
IRM 903 oil, 5 h/300°F (149°C)
Thickness
Increase:
Weight Increase:
ASTM Fuel B 5 h/70°F (21°C)
Thickness
Increase:
Weight Increase: |
0 to 10%
10%
0 to 10%
12% |
Sealability
ASTM F37 (Fuel A):
ASTM F37 (Nitrogen): |
0.03 mL/hr
0.4 mL/hr |
|
Volume Resistivity, ASTM D257: |
5 x 109 ohm-cm |
|
Dielectric Breakdown, ASTM D149: |
0.04 kV/mm (1 V/mil) |
| DIN 3535 Gas Permeability: |
0.05 cc/min |
| Creep Relaxation ASTM F38: |
18% |
| Flexibility, ASTM F147: |
10x |
Note: ASTM properties based on 1/16" sheet thickness except ASTM F38, which
is based on 1/32" sheet thickness. This is a general guide only and should not be the
sole means of accepting or rejecting this material. The data listed here falls within the
normal range of product properties but should not be used to establish specification
limits nor used alone as the basis of design. |
| *For applications above Class 300, consult your representative. |
|
Pressure - Temperature
Information:
PxT Chart |
|
|
M&Y AND PROPOSED ASTM GASKET
CONSTANTS:
|
THICKNESS |
1/16" |
1/8" |
|
M
Y psi (MPa) |
3.7
3515 (24.24) |
3.0
4014 (27.68) |
|
Gasket Constants
Gb psi (MPa)
a
Gs psi (MPa) |
512 (3.5)
0.355
13 (0.09) |
1716 (11.8)
0.209
70 (0.48) |
|
*Gasket Constants based on proposed
ASTM Draft 10.1 |
|
| |
|
|
AVAILABLE SHEET SIZES:
Nominal
Thickness |
Sheet Sizes
inches
mm
|
Order Code |
Sheets
Per Roll |
Approx.
Weight/Sheet
lbs (kg) |
| 1/64" 0.4mm |
60 x 63
60 x 126 |
1524 x 1600
1254 x 3200 |
DC05-060-063
DC05-060-126 |
20
10 |
4 (1.81)
7 (3.18) |
| 1/32" 0.8mm |
60 x 63
60 x 126 |
1524 x 1600
1254 x 3200 |
DC08-060-063
DC08-060-126 |
20
10 |
7 (3.18)
14 (6.35) |
1.0mm |
60 x 63
60 x 126
120 x 126 |
1524 x 1600
1254 x 3200
3048 x 3200 |
DC10-060-063
DC10-060-126
DC10-120-126 |
20
10
2 |
11
(5.00)
22 (9.98)
44 (19.96) |
| 1/16" 1.5mm |
60 x 63
60 x 126
120 x 126 |
1524 x 1600
1254 x 3200
3048 x 3200 |
DC15-060-063
DC15-120-126
DC15-120-126 |
10
5
2 |
14 (6.35)
28 (12.70)
55 (24.95) |
2.0mm |
60 x 63
60 x 126
120 x 126 |
1524 x 1600
1254 x 3200
3048 x 3200 |
DC20-060-063
DC20-060-126
DC20-120-126 |
10
5
2 |
22 (9.98)
44 (19.96)
88 (39.92) |
| 3/32" 2.5mm |
60 x 63
60 x 126 |
1524 x 1600
1254 x 3200 |
DC25-060-063
DC25-060-126 |
8
4 |
25 (11.34)
49 (22.23) |
| 1/8" 3.0mm |
60 x 63
60 x 126
120 x 126 |
1524 x 1600
1254 x 3200
3048 x 3200 |
DC30-060-063
DC30-120-126
DC30-120-126 |
8
4
1 |
27 (12.25)
54 (24.50)
108 (49.00) |
Note: Please inquire about
availability of 4.0mm and 5.0mm thicknesses and other sizes not listed.
Open PDF file of
this page
|
|
|
|
|
Warning:
Durlon gasket materials should never be recommended when both the
temperature and the pressure are at the maximums listed. Properties
and applications shown are typical. No application should be
undertaken by anyone without independent study and evaluation for
suitability. Never use more than one gasket in one flange joint, and never
reuse a gasket. Improper use or gasket selection could cause property
damage and/or serious personal injury. The data reported is a
compilation of field testing, field service reports and/or in-house testing.
While the utmost care has gone into publishing the information contained
herein, we assume no responsibility for errors. The information and
specifications contained in this website are subject to change without
notice. This revision cancels and obsoletes all previous editions. |
|
|
GASKET RESOURCES
INC.
|
CONTACT INFORMATION: |
|
Phone: |
Fax: |
E-mail |
| |
|
|
|
|
|
USA |
|
|
|
|
Sales:
|
140 Sheree Blvd
P.O. Box 565
Exton, PA 19341-0565 |
(866) 707-7300
(610) 363-5800
|
(610) 363-5881
|
sales@durlon.com
|
|
Technical: |
Houston, Texas |
(713) 856-9445 |
|
tech@durlon.com |
|
INTERNATIONAL |
|
(613) 968-1100 |
(613) 968-1099 |
intl@durlon.com |
|
|
Home
®Registered trademark Triangle Fluid Control Ltd.
Terms of Use
©2002-2011,
Gasket Resources Inc., All
Rights Reserved
 |
|