Revised
January 2011

DURLON®
CHEMICAL RESISTANCE CHART

A -
C -

NS -

  Acceptable
  Caution, depends on
  operating conditions
  Not Suitable

 

   
Previous

A    B    C    D    E    F    G    H    I    J    K    L    M    N    O
P   R    S    T    U    V    W    X   Z

Next

 


A - Acceptable      C - Caution (depends on operating conditions)       NS - Not Suitable
 

 
FLUID COMPRESSED PTFE FLEXIBLE GRAPHITE
8300 8400 8500 8600 8700 9000 9200W 9400 9600 FGS95 CFG,
FGL316
FGT316

Calcium Bisulfite

A

A

A

NS

C

A

A

A

A

A

A

A

Calcium Carbonate

A

A

A

A

A

A

A

A

A

A

A

A

Calcium Chloride

A

A

A

A

A

A

A

A

A

A

A

A

Calcium Hydroxide

A

A

A

A

A

A

A

A

A

A

A

A

Calcium Hypochlorite

C

A

C

C

C

A

A

A

A

A

A

A

Calcium Nitrate

C

C

C

C

C

A

A

NS

A

A

A

A

Caprolactam

NS

NS

NS

NS

NS

A

A

A

A

NS

NS

NS

Carbon Dioxide, dry

A

A

A

C

C

A

A

A

A

A

A

A

Carbon Dioxide, wet

A

A

A

C

C

A

A

A

A

A

A

A

Carbon Disulfide

NS

C

NS

NS

NS

A

A

A

A

A

A

A

Carbon Monoxide

A

A

A

NS

NS

A

A

A

A

A

A

A

Carbon Tetrachloride

NS

C

C

NS

NS

A

A

A

A

A

A

A

Caustic Soda (NaOH)

NS

A

C

C

NS

A

A

A

A

C

C

C

Chlorine, gas (dry) *

C

NS

NS

NS

NS

A

A

A

A

A

C

C

Chlorine, liquid (dry) *

NS

NS

NS

NS

NS

A

A

A

A

A

C

C

Chlorine (wet) *

NS

C

NS

NS

NS

A

A

A

A

A

NS

NS

Chlorine Dioxide

NS

NS

NS

NS

NS

A

A

NS

A

C

NS

NS

Chlorobenzene

NS

NS

NS

NS

NS

A

A

A

A

A

A

A

Chloroethane

NS

NS

NS

NS

NS

A

A

A

A

A

A

A

Chloroethylene

NS

NS

NS

NS

NS

A

A

A

A

A

C

C

Chloroform

C

A

C

NS

NS

A

A

A

A

A

A

A

Chromic Acid

NS

NS

NS

NS

NS

A

A

NS

A

A

A

A

Citric Acid

A

A

A

A

A

A

A

A

A

A

A

A

Coal Gas

NS

NS

NS

NS

C

A

A

A

A

A

A

A

Copper Sulfate

A

A

A

A

A

A

A

A

A

A

A

A

Corn Oil

A

C

C

NS

C

A

A

A

A

A

A

A

Cotton Seed Oil

A

A

A

NS

C

A

A

A

A

A

A

A

Creosote (Coal Tar)

A

A

A

NS

NS

A

A

A

A

A

A

A

Cresol

C

A

C

NS

NS

A

A

A

A

A

A

A

Crude Oil

A

A

A

NS

C

A

A

A

A

A

A

A

Cumene

NS

NS

NS

NS

C

A

A

A

A

NS

NS

NS

Cyclohexane

A

A

C

NS

C

A

A

A

A

A

A

A

Cyclohexanone

NS

NS

NS

NS

NS

A

A

A

A

A

A

A

* Durlon 9000/9000N is listed as an acceptable gasket material for dry chlorine service in Pamphlet 95 of The Chlorine
   Institute.  Gaskets must be cleaned for chlorine service before installation.
   
Previous

Next

A    B    C    D    E    F    G    H    I    J    K    L    M    N    O
P   R    S    T    U    V    W    X   Z

The properties or applications shown are typical.  Your specific application should not be undertaken without independent study and evaluation for suitability.  For specific application recommendations or for unusual conditions of fluid concentrations, internal pressures or, temperatures, please contact GRI.  This evaluation is based on field testing, customer experience, or in-house testing.  While the utmost care has been used in compiling this information, no guarantee can be given as to the actual performance experienced by the end user.

This Chemical Resistance Chart supersedes and obsoletes all previously issued charts.

Call GRI Technical Services at 1-713-856-9445 for specific recommendations


Warning: Durlon gasket materials should never be recommended when both the temperature and the pressure are at the maximums listed.  Properties and applications shown are typical.  No application should be undertaken by anyone without independent study and evaluation for suitability. Never use more than one gasket in one flange joint, and never reuse a gasket.  Improper use or gasket selection could cause property damage and/or serious personal injury.  The data reported is a compilation of field testing, field service reports and/or in-house testing.  While the utmost care has gone into publishing the information contained herein, we assume no responsibility for errors.  The information and specifications  contained in this website are subject to change without notice. This revision cancels and obsoletes all previous editions.


GASKET RESOURCES INC.
 

CONTACT INFORMATION:

Phone:

Fax:

E-mail

 

USA

 

Sales:

 

140 Sheree Blvd
P.O. Box 565
Exton, PA 19341-0565

(866) 707-7300
(610) 363-5800
 

(610) 363-5881

 

     sales@durlon.com

    

Technical:

Houston, Texas (713) 856-9445  

tech@durlon.com

INTERNATIONAL

  (613) 968-1100 (613) 968-1099
     intl@durlon.com

Home

®Registered trademark Triangle Fluid Control Ltd.
                       Terms of Use             ©2002-2011, Gasket Resources Inc., All Rights Reserved